Free Delivery Over £75

Excludes Islands, Highlands & Channel Islands

 
Next Day Delivery

UK Mainland Only

 
Contact Us On 01435 897501

24/7 Customer Support

Filterspec

JSP Filerspec Dust Masks

JSP - FilterSpec Eye & Respiratory Protection

The Unique FilterSpec Effortlessly Combines Both Eye & Respiratory Protection - Includes 3 Filters - Odour Filter Option -Available With P2 or P3 Valved Filters. Additional Filters Available-

Conforms to EN166.1.F & EN1827:1999:+A1:2009 -Very lightweight for user comfort 60g

Available with P2 & P3 Valved Filters- Special Valved Odour Filters also available

Extra filters can be purchased as required

Filter
Set Descending Direction

10 Items

per page
View as List Grid
  1. FilterSpec Pro P2 Goggles
    JSP - FilterSpec Pro Black - Eye & Respiratory Protection - JSP-AGE 120-201-100 -Goggles P2
    £30.32
    The Unique FilterSpec Effortlessly Combines Both Eye & Respiratory Protection - Conforms to EN166.1.F & EN1827:1999:+A1:2009 Black with 3 Filters - Goggles have an anti-mist and anti-scratch coating-P2 Valved FiltersAdditional P2 Filters Available Learn More
  2. Filterspec Pro P3 Goggles
    JSP - FilterSpec Pro Black Eye & Respiratory Protection - JSP-AGE130-201-100 -P3 Filter
    Rating:
    100% of 100
    £38.40
    The Unique FilterSpec Effortlessly Combines Both Eye & Respiratory Protection - Conforms to EN166.1.F & EN1827:1999:+A1:2009 Black with 3 Filters - Goggles have an anti-mist and anti-scratch coating-P3 Valved FiltersAdditional P3 Filters Available Learn More
  3. Filterspec Pro P2 Filter Odour
    JSP - FilterSpec Pro Black Eye & Respiratory Protection - JSP-AGE150-201-100 -Odour P2 Filter
    £33.50
    The Unique FilterSpec Effortlessly Combines Both Eye & Respiratory Protection - Conforms to EN166.1.F & EN1827:1999:+A1:2009 Black with 3 Filters - Goggles have an anti-mist and anti-scratch coating. -Odour Valved P2 Filters -Additional P2 Filters Available Learn More
  4. JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG139-325-800 - FilterSpec P3 -Smoke Lens
    JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG139-325-800 - FilterSpec P3 -Smoke Lens
    £17.90
    The Unique FilterSpec Effortlessly Combines Both Eye & Respiratory Protection - Conforms to EN166.1.F & EN1827:1999:+A1:2009 Black with 3 Filters - Smoke Lens has an anti-mist and anti-scratch coating-P3 Valved FiltersAdditional P3 Filters Available Learn More
  5. JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG134-121-100 - FilterSpec P3-Clear Lens
    JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG134-121-100 - FilterSpec P3-Clear Lens
    £17.90
    The Unique FilterSpec Effortlessly Combines Both Eye & Respiratory Protection - Conforms to EN166.1.F & EN1827:1999:+A1:2009 Black with 3 Filters - Clear Lens has an anti-mist and anti-scratch coating-P3 Valved FiltersAdditional P3 Filters Available Learn More
  6. JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG144-121-100 smoke lens
    JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG144-125-800 - FilterSpec P2 Odour -Smoke Lens
    £13.20
    FilterSpec-The Unique FilterSpec Effortlessly Combines Both Eye & Respiratory Protection - Conforms to EN166.1.F & EN1827:1999:+A1:2009 Black with 3 Filters - Smoke Lens has an anti-mist and anti-scratch coating. -Odour Valved P2 Filters -Additional P2 Filters Available Learn More
  7. JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG 129-125-800 - FilterSpec P2-Smoke Lens
    JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG 129-125-800 - FilterSpec P2-Smoke Lens
    £12.50
    FilterSpec -The Unique FilterSpec Effortlessly Combines Both Eye & Respiratory Protection - Conforms to EN166.1.F & EN1827:1999:+A1:2009 Black with 3 Filters - Smoke Lens has an anti-mist and anti-scratch coating-P2 Valved FiltersAdditional P2 Filters Available Learn More
  8. JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG144-121-100
    JSP - FilterSpec Eye & Respiratory Protection - JSP-ASG144-121-100 - FilterSpec P2 Odour -Clear Lens
    £13.20
    The Unique FilterSpec Effortlessly Combines Both Eye & Respiratory Protection - Conforms to EN166.1.F & EN1827:1999:+A1:2009 Black with 3 Filters - Clear Lens has an anti-mist and anti-scratch coating. -Odour Valved P2 Filters -Additional P2 Filters Available Learn More
Filter
Set Descending Direction

10 Items

per page
View as List Grid
 

Frequently Asked Questions

Protective masks, respiratory equipment (RPE) is divided into 2 main areas: (A) Filtering face Pieces (FFP) & (B) Air Supplied Equipment.

Additional information can be found within each category section:

01: What's the difference between FFP1, FFP2 and FFP3 Disposable masks?

The European safety standard EN149: 2001 + A1: 2009 for disposable protective masks includes performance tests in filter penetration; extended exposure test; flammability; breathing resistance and total inward leakage. Masks that meet this standard are classified according to their filtering efficiency & protection as FFP1, FFP2, FFP3.

FFP1 (80% Filter efficiency) Protection from non‐toxic contaminants in concentrations up to 4 x OEL or 4 x APF. Particles filtered are larger than 5 microns Dust, Fumes, Aqueous mists, Oils based mists.

FFP2(94% Filter efficiency) Protection from low to average toxicity contaminants in concentrations up to 12 x OEL or 10 x APF . Particle size filtration 2-5 microns - Fine dust, Aqueous / Oil-based mists.

FFP3 (99% Filter efficiency) Protection from toxicity contaminants in concentrations up to 50 x OEL or 20 x APF. Particles size less than 2 microns - Very fine dust, Fibres, Aqueous/ Oil-based mists.

Dolomite test for clogging signifies a mask with low breathing resistance in very dusty environments.

02: What are the safety standards for Reusable Half Masks?

Half mask respirators (Reusable masks) are required to meet the European standards EN140, EN141, 143 and EN371.

The European standard - EN140 covers the technical specifications for half masks. A half mask is defined as covering the nose, mouth & chin.

EN141 European standard -Gas filters for protection against specified gases and vapours or combined filters for protection against solids and/or liquid particles & specified gases and vapours.

Filters are classified as Class 1, Class 2 & Class 3 .

EN143 European standard - Filters for protection against particulates. These are classified according to their filtering efficiency P1, P2 & P3. P3 filters provide the highest level of filtration.

EN371 European standard - AX filters.

P1 (80% Filter efficiency) Protection from non‐toxic contaminants in concentrations up to 4 x OEL or 4 x APF. Particles larger than 5 microns Dusts, Fumes, Aqueous mists, Oils based mists.

P2(94% Filter efficiency) Protection from low to average toxicity contaminants in concentrations up to 12 x OEL or 10 x APF . Particle size filtration 2-5 microns - Fine dust, Aqueous / Oil-based mists.

P3(99% Filter efficiency) Protection from toxicity contaminants in concentrations up to 50 x OEL or 20 x APF. Particles size less than 2 microns - Very fine dust, Fibres, Aqueous/ Oil-based mists.

03: What are the safety standards for Full Face Masks?

EN136 European standard for Full Face masks. Negative pressure, powered or supplied air systems.

Full face masks are classified as:

Class 1 - Light Duty & Maintenance

Class 2 – General Duty & Maintenance

Class 3 – Heavy Duty – Fire Service

Full face masks when used with particulate filters provide the following APF protection levels. P2 filter APF 10 & P3 filter APF 40 when used with a full face mask.

04: What are the different types of powered air respirators?

The European safety standards for powered air respirators are the EN146 & EN12941 standard with the powered respirators classified into three protective categories, TH1, TH2 & TH3. (Turbo Hood)

The powered respirator includes hood & powered air unit.

The powered air respirators are a recommended solution as a dust mask for bearded personnel.

TH1P provides an APF protection factor of 10 (APF 10) & TH2P provide an APF protection factor of 20 (APF 20)

05: What is an air-fed respirator?

European standards EN270 & EN1835 incorporates the Helmet/hood (Covers the face) supplied with breathable air from a compressed air unit as well as the respirators operation. The adjustable continuous flow valve must incorporate a low warning device.

Standard EN1835 covers three classes LDH1, LDH2 & LDH3 (LDH=Light Duty Hose). The maximum permissible length of air line (Valve (Regulator) to the Air source (Compressor) is 30 metres EN270) & 10 metres EN1835.