AX Filter Cartridges- Organic gases BP< 65°C Working with solvents created by varnish, paints and adhesives -Single use filter (Code 9600)
Delivery Options:
FREE DELIVERY OVER £ 75 NET
Moldex 9600 AX filters are single-use gas filter cartridges for the Moldex 7000 half mask and 9000 full face mask. They protect against organic gases and vapours with a low boiling point, 65°C or below. This listing is a pack of 2 for £20.80.
AX filters protect against specific organic compounds with a low boiling point, 65°C and below. Standard A filters cover compounds boiling above 65°C. If your substance’s safety data sheet gives a boiling point at or below 65°C, check whether it needs an AX filter, and which compounds the filter is tested for.
A1 and A2 filters protect against organic vapours with a boiling point above 65°C, such as many paint and varnish solvents. AX filters cover only specific low-boiling compounds, and are single-use. Choose by your substance’s boiling point and the manufacturer’s list of tested compounds.
Low-boiling compounds can be released from the filter again after use, so an AX filter shouldn’t be reused or stored for later. The listing says it’s a single-use filter. Replace it after each use or work period, and throw it away even if it still feels fine.
Manufacturers and the EN 14387 standard generally advise against using AX filters for mixtures of low-boiling and other organic compounds, because earlier breakthrough can occur. If your task involves mixed solvents, check Moldex’s instructions and get advice before choosing a filter.
The listing says they’re for the Moldex 7000 and 9000 series, so they fit both the half mask and the full face mask through the EasyLock connection. If your job also creates dust or spray, Moldex sells P2 and P3 particulate filters for the same masks, which we stock.
Replace it after each use, because AX filters are single-use. During use, change it straight away if you smell or taste the vapour, or if breathing becomes harder. Follow Moldex’s instructions and your workplace’s change-out schedule, and don’t use filters past their date.
Yes. The filters don’t change the fit of the mask. The Moldex 7000 and 9000 are tight-fitting, so each wearer needs a face-fit test by a competent person, and facial hair along the sealing edge will stop the mask sealing properly and reduce protection.
Yes. Moldex 7000 series half masks and 9000 series full face masks share the same EasyLock bayonet filter system, so the same filters and cartridges fit both. This means you can standardise on one filter stock across your team even if some wearers use half masks and others use full face respirators.
A P3 filter is the highest particulate filter class under EN 143, capturing at least 99.95% of fine dust, fumes, mists and fibres. It's the standard choice for tasks generating fine airborne particles, such as cutting, grinding, sanding and powder handling, where lower P1 or P2 filters wouldn't provide adequate protection.
The letters indicate which gases and vapours a filter absorbs. A covers organic vapours, B inorganic gases, E acid gases and K ammonia. The number indicates capacity: A1 is low capacity, A2 medium. An ABEK filter covers all four groups, while A2 alone suits organic vapour tasks like solvent-based paint spraying.
Your choice depends on the substance identified in your COSHH assessment. Use a P-class particulate filter for dusts, fumes and mists; a gas filter (A, B, E or K) for vapours and gases; or a combination filter where both hazards are present. Always check the substance safety data sheet before selecting a filter class.
Particulate filters should be changed when breathing resistance noticeably increases or the filter is damaged or soiled. Gas and vapour cartridges have a limited service life once the seal is broken, even if lightly used, and should be replaced according to the manufacturer's guidance or your workplace's documented change-out schedule.
No. Filters and cartridges are consumable items and must never be washed, blown out with compressed air, or otherwise cleaned, as this damages the filter media and destroys its performance. Only the mask body itself is cleaned and reused; filters are replaced once expired, clogged or contaminated.
Yes. Moldex filters carry a use-by date printed on the packaging, typically several years from manufacture when stored sealed in cool, dry conditions. Once the seal is opened, shelf life shortens considerably, particularly for gas and vapour cartridges, so record the opening date and follow the manufacturer's in-use guidance.
A pre-filter is a thin particulate layer fitted over a gas or vapour cartridge to capture dust and mist before it reaches the main filter. It's cheap to replace and extends cartridge life in dusty conditions, such as spray painting, but it isn't a substitute for a properly rated P-class filter on its own.
Yes. Moldex particulate filters are tested to EN 143 and gas and vapour cartridges to EN 14387, the recognised UK and European standards for respiratory filters. Check the filter carries a clear class marking (such as P3 or A2) along with CE or UKCA marking before use.