COVID-19 UPDATE:        ONLINE ORDERS ONLY

WE HAVE A SELECTION OF FFP2, FFP3 MASKS AS WELL AS RESUABLE HALF MASKS AVAILABLE IN STOCK TO ORDER NOW

GENERAL PUBLIC/OFFICE STAFF - BULK DEALS -NEXT DAY DELIVERY  : FACE COVERINGS AVAILABLE 

FACE FIT TEST KITS BACK IN STOCK

CURRENT DELIVERY -1-3 DAYS

 

Jetstream Dust Constructor Kit

The powered air unit is fully approved to EN12941:1999 delivering air at 180 Litres per minute, twice the current standard.

APF of 20x Work Exposure limit for use with very fine dusts, fibres fumes and aqueous mists.

No face fitting required.  Suitable for gents with small beards.

SKU#:
2001
Availability: In stock
SKU
2001

Jetstream Powered Air Constructor Kit

(Code CBP020-000-000)

Powered Air Features:

  • Ready to go unit
  • light only weighing 765 grams
  • Mark7 Helmet airfed unit with polycarbonate Visor
  • Waist mounted unit
  • Rechargeable battery
  • Kit contains - unit, charger and filter 

No face fitting required

Write Your Own Review
You're reviewing:Jetstream Dust Constructor Kit
Your Rating

Delivery Options Available:

  • Standard Delivery: 2-3 Days - (£4.95-£ 6.20)
  • Next Day Delivery: £6.95
  • Saturday Delivery:(Order Before 2pm Friday) (FREE OVER £ 200)
  • Sunday Delivery:(Order before 2pm Friday) (FREE OVER £ 200)
  • Free Delivery Over £ 70 - Excludes Islands, Highlands & Channel Islands
 

Frequently Asked Questions

Protective masks, respiratory equipment (RPE) is divided into 2 main areas: (A) Filtering face Pieces (FFP) & (B) Air Supplied Equipment.

Additional information can be found within each category section:

01: What's the difference between FFP1, FFP2 and FFP3 Disposable masks?

The European safety standard EN149: 2001 + A1: 2009 for disposable protective masks includes performance such a tests in this filter penetration; extended exposure test; flammability; breathing resistance and total inward leakage. Masks that meet this standard are classified according to their filtering efficiency & protection as FFP1, FFP2, FFP3.

FFP1 (80% Filter efficiency) Protection from non‐toxic contaminants in concentrations up to 4 x OEL or 4 x APF. Particles larger than 5 microns Dusts, Fumes, Aqueous mists, Oils based mists.

FFP2(94% Filter efficiency) Protection from low to average toxicity contaminants in concentrations up to 12 x OEL or 10 x APF . Particle size filtration 2-5 microns - Fine dusts, Aqueous / Oil based mists.

FFP3 (99% Filter efficiency) Protection from toxicity contaminants in concentrations up to 50 x OEL or 20 x APF. Particles size less than 2 microns - Very fine dust, Fibres, Aqueous/ Oil based mists.

Dolomite test for clogging signifies a mask with low breathing resistance in very dusty environments.

02: What are the safety standards for Reusable Half Masks?

Half mask respirators (Reusable masks) are required to meet the European standards EN140, EN141, 143 and EN371.

The European standard - EN140 covers the technical specifications for half masks. A half mask is defined as covering the nose, mouth & chin.

EN141 European standard -Gas filters for protection against specified gases and vapours or combined filters for protection against solids and/or liquid particles & specified gases and vapours.

Filters are classified as Class 1, Class 2 & Class 3 .

EN143 European standard - Filters for protection against particulates. These are classified according to their filtering efficiency P1, P2 & P3. P3 filters provide the highest level of filtration.

EN371 European standard - AX filters.

P1 (80% Filter efficiency) Protection from non‐toxic contaminants in concentrations up to 4 x OEL or 4 x APF. Particles larger than 5 microns Dusts, Fumes, Aqueous mists, Oils based mists.

P2(94% Filter efficiency) Protection from low to average toxicity contaminants in concentrations up to 12 x OEL or 10 x APF . Particle size filtration 2-5 microns - Fine dusts, Aqueous / Oil based mists.

P3(99% Filter efficiency) Protection from toxicity contaminants in concentrations up to 50 x OEL or 20 x APF. Particles size less than 2 microns - Very fine dust, Fibres, Aqueous/ Oil based mists.

03: What are the safety standards for Full Face Masks?

EN136 European standard for Full Face masks. Negative pressure, powered or supplied air systems.

Full face masks are classified as:

Class 1 - Light Duty & Maintenance

Class 2 – General Duty & Maintenance

Class 3 – Heavy Duty – Fire Service

Full face masks when used with particulate filters provide the following APF protection levels. P2 filter APF 10 & P3 filter APF 40 when used with a full face mask.

04: What are the different types of powered air respirators?

The European safety standards for powered air respirators are the EN146 & EN12941 standard with the powered respirators classified into three protective categories, TH1, TH2 & TH3.(Turbo Hood)

The powered respirator includes hood & powered air unit.

The powered air respirators are a recommended solution as a dust mask for bearded personnel.

TH1P provides and APF protection factor of 10 (APF 10) & TH2P provide an APF protection factor of 20 (APF 20)

05: What is an air fed respirator?

European standards EN270 & EN1835 incorporates the Helmet/hood (Covers the face) supplied with breathable air from a compressed air unit as well as the respirators operation. The adjustable continuous flow valve must incorporate a low warning device.

Standard EN1835 covers three classes LDH1, LDH2 & LDH3 (LDH=Light Duty Hose). The maximum permissible length of air line (Valve (Regulator) to the Air source (Compressor) is 30 metres EN270) & 10 metres EN1835.